Chapter 11 Waveform Record

11-2

MSO1000Z/DS1000Z User’s Guide

Common Settings

Press UtilityRecordRecord to turn on or off the waveform record function.

1. Record Waveform

Before recording the waveform, you can refer to the introduction in "Record

Option" to set the waveform recording parameters. Press Record to start

recording the waveform. During the recording, the current recording information

as shown in the figure below is displayed at the upper right corner of the screen.

"●" in the menu changes to "■" automatically. At this point, press Record
again to stop recording.

Tip
Under the waveform recording menu, pressing RUN/STOP can also start and
stop the recording.

2. Play

Press Play to start playing the waveform recorded. For more details, please

refer to the introduction in "

Playback Option".

3. Stop

During the playback, you can press Stop to stop the playback.

4. Current Frame

Press Current and use

to set the current frame. The default is the

maximum number of frames recorded currently. During the setting, the screen

will display the corresponding waveform of the current frame synchronously,

namely manual playback.

5. Step Direction

Press Step Dir to select the single frame playback direction of the recorded

waveform.

: press SINGLE to play the single frame forward (namely the

single frame playback sequence is the same as the waveform record

sequence) and the number of the frame is incremental.

: press SINGLE to play the single frame backward (namely the

single frame playback sequence is opposite to the waveform record

sequence) and the number of the frame is decremental.

6. The Last/First Frame

You can view the last or first frame of waveform. Pressing

can jump to

the last frame of the recorded waveform; pressing

can jump to the first

frame of the recorded waveform.