Rose Electronics UltraView Remote 2 User Manual

Page 24

Advertising
background image

20

ULTRAVIEW REMOTE 2 INSTALLATION AND OPERATIONS MANUAL

Hotkey / KVM Port

Declare the hot key sequence, or Remote Port Direct address that will cause the KVM switch module to link with the
required host system. Remote Port Direct addresses must be entered within square brackets. To set-up the hotkey
values used to switch to a given CPU port, the following information is used to create the hot key sequence:

+ means press down the key that follows

– means release the key that follows

+– means press down and release the key that follows

To switch to CPU port #1, the Hotkey / KVM port sequence would be +-Ctrl+-1+-Enter, to switch to CPU port #8, the
sequence would be +-Ctrl+-8+-Enter, the sequence to switch to CPU port #15 would be +-Ctrl+-1+-5+-Enter. A list of
the valid hotkey codes are given in Appendix J.

Logging and Status

This screen provides various details about the user activity on the UltraView Remote 2 .

Note: The log has a maximum capacity of 1000 event lines. After 1000 entries, the oldest entries are overwritten. If
log data are important to your installation, ensure a regular backup procedure or use the Syslog Server IP Address
option to send log information automatically to another system.

The first three (3) columns show the date the event
occurred.

The next column is the time the event occurred.

The last column describes the type of event with the
users name and the access method.

The “Clear log” tab will clear all entries in the log

The “Refresh” tab will refresh the log list

The “Syslog Server IP Address field is an optional
field where you can enter an IP address to send the
status log.

The “Save” tab will save the log file

The “Cancel” tab will exit the log menu and return to
the main menu


To copy and paste the log
You can copy the information listed within the log and paste it into another application. While viewing the log screen,
press Ctrl and C, to copy the data into the clipboard. Start a text application (i.e. Word, WordPad, Notepad) press
Ctrl and V, or right mouse click and ‘Paste’.

This basically covers the configuration of the input module and allows user access to the unit. Following is the
additional KVM switch module configuration. Some configurations are needed to assure proper functionality and
other configurations are optional.












Advertising