Rose Electronics CrystalView DVI Micro User Manual

Page 5

Advertising
background image

EDID Settings

The factory EDID settings can be changed by the following procedure:

1. Apply power to the DVI monitor
2. Connect the Transmitter unit to the monitor
3. Plug in the 5V DC power adapter into the power jack on the transmitter
4. Verify that the Transmitter LED blinks rapidly for a few seconds
5. When the blinking stops, the EDID information from the connected

DVI monitor is saved in the Transmitter unit

6. Disconnect the Transmitter from the DVI monitor, unplug the power adapter and

connect the Transmitter to the computer’s DVI port

7. Connect the Receiver unit to the DVI monitor and connect the power adapter to the

Receiver’s power jack

8. Connect the multimode fiber cable between the Transmitter and Receiver units
9. Re-Start the connected computer

NOTE: If the Transmitter’s power LED does not light up, connect the power adapter to the
power jack
NOTE: Multi-mode SC-type fiber cable must be used

CAUTION
Use only the included DC adapter (5V, 2A) for the receiver unit. The transmitter
uses the computer power. No external DC adapter is required for the transmitter. Some
computers cannot supply sufficient power to the transmitter. In this case, use the external DC
adapter for the receiver.

Specifications

Resolution

Up to 1920 x 1200

Bandwidth

1.65Gbps, Single Link DVI Video

Connectors

a) DVI-D 24 pin male video connector

b) SC type fiber connector

Power

100 – 240 VAC – 5VDC, 2A. 1.0W Max (Transmitter or Receiver)

Transmitter: optional +5V / 2A adapter. Receiver: +5V / 2A adapter

Dimensions

(W x D x H)

1.57 x 2.61 x 0.6 inches

40.0 x 66.4 x 15.0 mm

Environmental

Operating Temp

Storage Temp


32°F - 122°F (0°C - 50°C)
-4°F - 158°F (-20°C - 70°C)

Optical Characteristics

Source

850nm VCSEL

O/E Converter

Pin Photo Diode

Cable Type

50/125 SC type multi-mode fiber