30" gas range installation instructions, Electrical requirements, Model and serial number location – Electrolux 318201775 User Manual

Page 3

Advertising
background image

3

30" GAS RANGE INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1.

Read all instructions contained in these installation
instructions before installing range.

2.

Remove all packing material from the oven
compartments before connecting the electrical supply
to the range.

3.

Observe all governing codes and ordinances.

4.

Be sure to leave these instructions with the consumer.

5.

Note: For operation at 2000 ft. elevations above see
level, appliance rating shall be reduced by 4 percent
for each additional 1000 ft.

Important Note to the Consumer

Keep these instructions with your owner's guide for future
reference.

Optional Items Available:

A Stainless Steel Kick plate
A Black Knob kit
Those kits can be ordered for purchase through an Electrolux
Service Center at 1-877-4ELECTROLUX (1-877-435-3287).

1.

Model and Serial Number Location

The serial plate is located at back of the appliance.

When ordering parts for or making inquires about your
oven, always be sure to include the model and serial
numbers and a lot number or letter from the serial plate
on your oven.

Figure 2

Gas Connector

Preferred Method
Grounding type
wall receptacle

Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong.

Power supply cord with 3-
prong grounding plug.

Figure 3

2.

Electrical Requirements

120 volt, 60 Hertz, properly grounded dedicated circuit
protected by a 15 amp circuit breaker or time delay fuse.

Do not use an extension cord with this range.

Grounding Instructions

IMPORTANT Please read carefully.

For personal safety, this appliance must be properly
grounded.

The power cord of this appliance is equipped with a 3-
prong (grounding) plug which mates with a standard 3-
prong grounding wall receptacle (see Figure 3) to
minimize the possibility of electric shock hazard from the
appliance.

The wall receptacle and circuit should be checked by a
qualified electrician to make sure the receptacle is
properly grounded.
Where a standard 2-prong wall receptacle is installed, it
is the personal responsibility and obligation of the
consumer to have it replaced by a properly grounded 3-
prong wall receptacle.

Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.

Disconnect electrical supply cord from

wall receptacle before servicing range.

Serial plate location