Installation, Dear installer, Provision of ventilation – ELAN Home Systems U102110-07 User Manual

Page 26: Location of cooker

Advertising
background image

26

Installation

Dear Installer

Before you start your installation, please
complete the details BELOW.

If your customer has a problem relating to your
installation they will be able to contact you
easily.

Thank you

Installer’s Name

Installer’s Company

Installer’s Telephone number

You must be aware of the
following safety requirements &
regulations

Prior to installation, ensure that the local distribution

conditions (nature of the gas and gas pressure) and the

adjustment of the appliance are compatible.

This appliance shall be installed in accordance with the

regulations in force and only in a well ventilated space.

Read the instructions before installing or using this

appliance.

In the UK the regulations and standards are as follows:-

In your own interest and that of safety, it is law that all

gas appliances be installed by competent persons.

CORGI registered installers undertake to work to safe

and satisfactory standards. Failure to install the appliance

correctly could invalidate any warranty or liability claims

and lead to prosecution. The cooker must be installed in

accordance with

All relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000,
For Natural Gas - BS 6172 : 1990 and BS
6891 : 1998

For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS
5482-2:1977, (when the installation is in a
caravan or other non permanent dwelling), or
BS 5482-3:1999 , (when the installation is in a
boat).
The Gas Safety (Installation and Use)
regulations 1998.
The relevant Building / IEE regulations.

Provision of Ventilation

This appliance is not connected to a combustion products

evacuation device. Particular attention shall be given to

the relevant requirements regarding ventilation.

The room containing the cooker should have an air

supply in accordance with BS 5440 Part 2 : 2000. All

rooms require an openable window or equivalent, while

some rooms require a permanent vent in addition to the

openable window. The cooker should not be installed in a

bedsitting room with volume less than 20m

3

. If it is

installed in a room of volume less than 5m

3

an air vent of

effective area 100cm

2

is required; if it is installed in a

room of volume between 5m

3

and 10m

3

, an air vent of

effective area 50cm

2

is required; while if the volume

exceeds 11m

3

, no air vent is required.

If there are other fuel burning appliances in the same

room, BS 5440 Part 2 : 2000 should be consulted to

determine the requisite air vent requirements.

Location of Cooker

The cooker may be installed in a kitchen/kitchen diner but

NOT in a room containing a bath or shower.

NOTE:

An appliance for use on LPG shall not be installed in

a room or internal space below ground level. e.g. in a

basement.