8-10 DIAGNOSIS CODE

Step

Key position

Description

1

Tune the key switch to

the “RUN” position .

OFF

RUN

START

(a) Lightning 2 sec and go out forever .

Not see any problem .

Lamp

(b) Lightning 2 sec and go out 4 sec, then lightning again .

There is some problem .

Refer to step 2

Lamp

2

OFF

RUN

START

(a) After the 4 sec the lamp repeats turning on and off .

Go out 4 sec

This sample, failure code is “2-1” . Two (2) turning on and

off, and go out 2 sec then turning on 0 .4 sec . After this go

out 4 sec and repeat the code again .

(b) If there is another failure, the lamp indicates continuity

with new code . Refer to step 3 .

This engine has the failure diagnosis system to know that low voltage of DC battery and each

wiring whether disconnecting or electrical short circuit . The ECU monitors engine various

conditions for the system when tune the key to the “RUN” (ON) position, “START” (cranking) or

after start the engine . However, this is required the warning lamp or a lamp for DC12V to indicate

of the failure code . The warning lamp and so on is prepared as optional .

8-10-1 HOW TO OPERATION

When troubleshooting with the failure diagnosis, disconnect the grey wire to oil pressure switch .

If the wire will be not disconnected, the lamp will be lightning cause of the engine stopped and

no oil pressure .
If there is failure the components wiring, the warning lamp repeats turning on and off .
Finally, re-connect the grey wire to the oil pressure switch, after troubleshooting with failure

diagnosis system .

8-10-2 INDICATION MEANS and PROCEDURE