3. PRE-OPERATION CHECKS

4. ELECTRIC STARTER MODELS

NOTE
Engine shipped from our factory is without oil.
Before starting engine, fill with oil. Do not over-fill.

1. CHECK ENGINE OIL (See Fig. 2)

Before checking or refilling engine oil, be sure the engine is
located on stable, level surface and stopped.

■ Do not screw the oil gauge into the oil filler neck to check oil

level. If the oil level is low, refill to the upper level with the
following recommended oil.

■ Use 4-stroke automotive detergent oil of API service class

SE or higher grade.

■ Select the viscosity based on the air temperature at the

time of operation as shown in the table. (See Fig.2-①)

CAUTION

Air cooled engines run hotter than automotive

engines.

The use of non-synthetic multi-viscosity oils

(5W-30, 10W-30, etc.) in temperatures above

40°F(4°C) will result in higher then normal oil

consumption. When using a multi-viscosity oil,

check oil level more frequently.

Oil capacity (Upper level) :

Oz (L)

SX17/21 . . . . . . . . . . . . . . . . . . . .20.3 (0.6)

SX30 . . . . . . . . . . . . . . . . . . . . . .33.8 (1.0)

2. CHECK FUEL (See Fig. 3)

WARNING

Do not refuel while smoking, near an open flame

or other such potential fire hazards. Otherwise

fire accident may occur.

NOTE
THIS ENGINE IS CERTIFIED TO OPERATE ON
AUTOMOTIVE UNLEADED GASOLINE.

Fuel tank capacity :

Qts (L)

SX17 . . . . . . . . . . . . . . . . . . . . . . .3.6 (3.4)

SX21 . . . . . . . . . . . . . . . . . . . . . . .3.8 (3.6)

SX30 . . . . . . . . . . . . . . . . . . . . . . .6.4 (6.1)

■ Stop the engine and open the cap.

■ Close the fuel valve before filling the fuel tank.

■ Do not fill above the top of the fuel filter screen

(marked ❶), or the fuel may overflow when it heats up later
and expands.

For electric starter operation, proper electric wiring
arrangements are needed before normal engine operation.

WIRING DIAGRAM

(SX17,21)

Spark plug

Black

Black

Black

Stop switch (Safety Key)

Ignition coil

Flywheel

Stop switch

(Speed Conrol Lever)

Electric starter

AC120V

Push switch

(Push Button Electric Start)

AC120V

(SX30)

Spark plug

Black

Lamp

Lamp coil

Magneto

Ignition coil

Black

Blue

Light Blue

Black

Stop switch (Safety Key)

Stop switch

(Speed Conrol Lever

)

Electric starter

AC120V

Push switch

(Push Button Electric Start)

AC120V

Optional hardware shown by dotted lines.

■ When filling the fuel tank, always use the fuel filter screen.

■ After refueling, tighten the fuel cap (rotate clockwise) until

it makes a physical stop, there will be a relief in resistance
just before the physical stop.

This will form a vapor seal between the tank and fuel cap.

■ Wipe off any spilled fuel before starting the engine.