NOTE :

When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.

To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.

Be sure to ground the generator if
the connected electrical device is
grounded.

TWIST

Style

Ampere

Receptacle

AC plug

Description

up to 20A

NEMA

5-20R

NEMA

5-20P

GFCI (Ground Fault
Circuit Interrupter)
Receptacle,
duplex(REC1)

up to 20A

NEMA

L14-20R

NEMA

L14-20P

Locking
Receptacle(REC2)

up to 30A

NEMA

L5-30R

NEMA

L5-30P

Locking
Receptacle(REC3)

up to 30A

NEMA

L14-30R

NEMA

L14-30P

Locking
Receptacle(REC4)

TABLE 1

WARNING

The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.