Troubleshooting – Subaru Robin RGX2900 User Manual

Page 35

Advertising
background image

ENGLISH

FRANÇAISE

ESPAÑOL

- 30 -

11. TROUBLESHOOTING

When generator engine fails to start after several attempts, or if no electricity is
available at the output socket, check the following chart. If your generator still fails
to start or generate electricity, contact your nearest SUBARU Industrial Power
Products dealer or service shop for further information or corrective procedures.

When Engine Fails to Start:

When No Electricity Is Generated at Receptacle:

Check if choke lever is in its proper
position.

Set the choke lever to “CLOSE” position.

Check if fuel valve is open.

If closed, open fuel valve.

Check fuel level.

If empty, refill fuel tank making sure not to
overfill.

Check if engine switch is in OFF.

Turn engine switch to ON.

Check to make sure generator is not
connected to an appliance.

If connected, turn off the power switch on
the connected appliance and unplug.

Check spark plug for loose spark plug
cap.

If loose, push spark plug cap back into
place.

Check spark plug for contamination.

Remove spark plug and clean electrode.

Check to make sure AC circuit breaker is
in the “ON” position.

After making sure that the total wattage
of the electrical appliance is within
permissible limits and there are no
defects in the appliance, turn the AC
circuit breaker to the “ON” position.
If breakers continue to actuate, consult
your nearest servicing dealer.

Check AC receptacle and DC terminals
for loose connection.

Secure connection if necessary.

Check to see if engine starting was
attempted with appliances already
connected to generator.

Turn off switch on the appliance, and
disconnect cable from receptacle.
Reconnect after generator has been
started properly.

Low power.

Carbon brushes are excessively worn

Advertising
This manual is related to the following products: