When the no-fuse breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
Robin

dealer or service shop.

To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.

Be sure to ground the generator if
the connected electrical device Is
grounded.

WARNING

TWIST

The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.

CAUTION

up to 30A

up to 20A

up to 20A

NEMA

5-20A

NEMA

L5-20R

NEMA

L14-30R

NEMA

5-20P

NEMA

L5-20P

NEMA

L14-30P

GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex

(REC1)

Locking Receptacle
(REC2)

Locking Receptacle
(REC4)

Style

Ampere

Receptacle

AC plug

Description

up to 30A

NEMA

L5-30R

NEMA

L5-30P

Locking Receptacle
(REC3)