FULL POWER SWITCH

Select the voltage using the FULL
POWER SWITCH in accordance with the
electrical appliance.
Refer to TABLE 2.

120V 120V

240V

Change the FULL POWER SWITCH
after turning the no-fuse breaker to
"OFF".

CAUTION

GFCI RECEPTACLE

After starting the engine, check the GFCI for proper functioning by the following
test procedure.

Push blue TEST button, The red RESET button will pop out exposing the word
TRIP. Power is now off at the outlets protected by the GFCI, indicating that the
device is functioning properly.

If TRIP dose not appear when testing, do not use the generator. Call a
qualified electrician.

To restore power, push RESET button.

If the RESET button pops out during operation, stop the generator
immediately and call a qualified electrician for checking generator and
the appliances.

WARNING

NOTE :

Voltmeter always indicates the lower voltage whichever the FULL POWER
SWITCH is set.

TABLE 2

Switch position

Lower Voltage Receptacle

Higher Voltage Receptacle

120V

Activated full rated output

N.A

120/240V

Activated half of rated output

Activated full rated output