FIGURE A-1. GPIB COMMANDS

A.8

*OPC? — OPERATION COMPLETE QUERY

*OPC?

Syntax:

*OPC?
Return value: <1> (ASCII) placed in output queue when power supply has completed operation.

Description: Indicates when pending operations have been completed.When all pending operations are com-

plete (all previous commands have been executed and changes in output level have been completed)
a “1” is placed in the Output Queue. Subsequent commands are inhibited until the pending operations
are completed. *OPC? is intended to be used at the end of a command line so that the application pro-
gram can monitor the bus for data until it receives the “1” from the power supply Output Queue. (See
example, Figure A-1.)

A.9

*OPT? — Options Query

*CLS

Power supply clears status data.

*ESE 60

Power supply enables bits 5, 4, 3 and 2, allowing command error, execution
error, device dependent error and query error to set the Event Status
Summary bit when an STB command is executed.

*ESE?

Returns 60, (value of the mask) verifying that bits 5, 4, 3 and 2 are enabled.

*ES

Unknown command will set command error (Bit 5).

*ESR?

Returns 32 (bit 5 set), indicating Command Error has occurred since the last
time the register was read.

*IDN?

Controller returns character string: "KEPCO,MBT,1,V3.0-3.0"

*OPC

Allows status bit 0 to be set when pending operations complete

VOLT 21;CURR 3

Sets output voltage to 21V, output current to 3A

*ESR

Returns 129 (128 + 1, power on, bit 7 = 1, operation complete, bit 1 = 1)

*ESR

Returns 0 (event status register cleared by prior *ESR?)

VOLT 15;CURR 5;*OPC? Sets output voltage to 15V, output current to 5A, puts “1” on output bus when

command operations are complete.

*RST

Power supply reset to power on default state.

*SRE 40

When ESB or QUES bits are set (Table A-3), the Request for Service bit will
be set.

*SRE?

Returns the value of the mask (40).

*STB?

For example, the Power supply responds with 96 (64 + 32) if MSS and the
Event Status Byte (Table A-3) summary bit have been set. The power supply
returns 00 if no bits have been set.

VOLT 25

Power supply voltage commanded to 25V.

VOLT:TRIG 12

Programs power supply voltage to 12V when *TRG received.

INIT

Trigger event is initialized.

*TRG

Power supply reverts to commanded output voltage of 12V.

*TST?

Power supply executes self test and responds with 0 if test completed
successfully, with 1 if test failed.