Agency approvals, Inspection, Installation – Energy Tech Laboratories DHG240 User Manual

Page 4

Advertising
background image

035-17233-000-C-0702

4

Unitary Products

REFERENCE

Additional information on the design, installation, operation
and service of this equipment is available in the following ref-
erence forms:

44-320-10 - Barometric Relief Damper Accessory

530.18-N6.1V - Propane Conversion Accessory (USA)

530.18-N6.2V - High Altitude Accessory (Nat. Gas)

530.18-N6.3V - High Altitude Accessory (Propane)

RENEWAL PARTS:

Refer to the Renewal Parts Manual for complete listing of
replacement parts on this equipment.

All forms referenced in this instruction may be ordered from:

Standard Register
2101 West Tecumseh Road
Norman, Oklahoma 73069
Toll Free Phone (877) 318-9675
Toll Free Fax: (877) 379-7920

AGENCY APPROVALS

Design certified by ETL as follows:

1.

For use as a forced air furnace with cooling unit.

2.

For outdoor installation only.

3.

For installation on combustible material.

4.

For use with natural gas or propane gas.

INSPECTION

As soon as a unit is received, it should be inspected for possi-
ble damage during transit. If damage is evident, the extent of
the damage should be noted on the carrier's freight bill. A
separate request for inspection by the carrier's agent should
be made in writing. Refer to Form 50.15-NM for additional
information.

INSTALLATION

LIMITATIONS

These units must be installed in accordance with the follow-
ing national and local safety codes:

1.

National Electrical Code ANSI/NFPA No. 70.

2.

National Fuel Gas Code Z223.1.

3.

Gas-Fired Central Furnace Standard ANSI Z21.47a.

4.

Local gas utility requirements.

Refer to Table 2 for Unit Application Data and to Table 4 for

Gas Heat Application Data.

After installation, the unit must be adjusted to obtain a tem-
perature rise within the range specified on the unit rating
plate.

If components are to be added to a unit to meet local codes,
they are to be installed at the dealer's and/or the customer's
expense.

Size of unit for proposed installation should be based on heat
loss/heat gain calculation made according to the methods of
the Air Conditioning Contractors of America (ACCA).

This furnace is not to be used for temporary heating of build-
ings or structures under construction.

Improper installation may create a condition where
the operation of the product could cause personal
injury or property damage.

TABLE 2: UNIT APPLICATION DATA

MODEL SIZE

15 TON

20 TON

Voltage Variation,

Min./Max

1

1

Rated in accordance with ARI Standard 110, utilization
range “A”.

208/230-3-60

187/253

460-3-60

414/506

575-3-60

518/630

Supply Air CFM, Min./Max.

4500/7200

6000/9400

Wet Bulb Temperature (°F) of air

on Outdoor Coil Min./Max.

57/72

Dry Bulb Temperature (°F) of air

on Outdoor Coil Min./Max.

2

2

A low ambient accessory is available for operation
down to 0°F.

25/120

Advertising