Electronic controller options, Fan drive configuration – Eaton Compressor & Fabrication CONFERENCE SYSTEM SDC 8200 User Manual

Page 4

Advertising
background image

4

Eaton Electro-hydraulic Fan Drive System E-SYFD-MROO1-E3 October 2008

Electronic

Controller

Options

TCA Electronic Controller
The TCA at the heart of the

EH Fan Drive System, is a

rugged, fully encapsulated

digitally programmable con-

troller specially designed for

mobile environments.

It is prepared for CANbus

communications on a ve-

hicle network. Software for

controlling the EH Fan Drive

System is loaded in the con-

troller memory at the factory.

Control software parameters

are adjusted via RS 232 hook-

up to a laptop computer.

The TCA controller is available

for both 12 V or 24 V vehicle

power systems. With 5 con-

figurable inputs and 2 Pulse

Width Modulated (PWM)

outputs, the TCA can inter-

face with a variety of system

components and drive up to

two electro-hydraulic valves.

Two Channel Amplifier (TCA)

EFX Electronic Controller
Eaton EFX electronic control-

lers and I/O modules provide

a full range of electronic con-

trols. With an array of control-

ler options and I/O modules,

an EFX system can address

any application need. All EFX

products are IP67 rated and

are built for harsh mobile

and industrial application

environments. The EFX line is

programmed and configured

using Eaton CONTROL F(x)™

software.

Applications
Excavators, forestry,

telehandlers, utility vehicles,

cranes, ag machinery, paving

Specifications
Four different EFX controllers

and 3 I/O expansion modules

provide analog, digital, and

frequency inputs as well as

digital, PWM, and current-

controlled outputs. Each EFX

controller has both CANopen

and J1939 interfaces.

EF(x) Controllers

Fan Drive

Configuration

Power Requirement
• 12 VDC or 24 VDC

Laptop or PC

Communication
• RS232 for

communication with GUI

Inputs
• Five user configurable

inputs

– Two Thermistor inputs
– Two Digital or Switch

inputs

– Engine Control

Module cooling

command voltage

signal

Or
• Optional CANbus signal

Outputs
• PWM current

controlled driver for

proportional flow control

• On-off driver for fan

off or fan reverse

Mechanical
• Polymer enclosure
• Fully encapsulated

electronics

• Flying lead harness

with 10-pin MetriPak

connector

• Two Mounting flanges:

#8 fasteners

• Dual color LED for

status and diagnosis

Environment
• Operating temperature:

-40°C to +85°C

• Meets EMC standards

off-road vehicle

• Reverse battery and load

dump protection

• Input/output short circuit

protection

• UV resistant
• Water: temporary

immersion

• Random vibration

5.8 Grms

• Shock: 50 G

Advertising