Eaton Electro-hydraulic Fan Drive System E-SYFD-MROO1-E3 October 2008

Integrated

Fan Drive System

Fixed-displacement Pump
The system cooling strategy

is based on one ECM input,

two Temperature Inputs and

two Digital Inputs. In some

cases, the ECM signal is too

noisy or too weak to control

a hydraulic circuit. The TCA

or EFX solution amplifies and

conditions the ECM signal to

be used on a hydraulic circuit.

A fixed displacement pump

fan drive system is suited for

a smaller and simpler cooling

system. A fixed displacement

pump is unable to alter it’s

displacement to slow the fan

speed with respect to the

cooling demand. The excess

flow generated by the pump

is returned to the tank, which

leads to generation of heat

and energy losses.

Fixed displacement pumps

are best suited for Fan Drive

Systems below 10 HP.

Inputs from sensors

and the engine

TCA/EFX