PLENUM EQUIPMENT BOX

INSTALLATION INSTRUCTIONS

* In compliance with NEC Article 300.22c

When External Wiring Connections to the Box are in made in accordance with those requirements.

GENERAL INSTRUCTIONS

This version can be attached to any Flat Surface using the

Optional Supplied Flat Plate

or

Suspended using the

Optional Extra Cost Hanging Kit,

In all cases all Cables are enclosed in

Conduit to and from the Plenum Box. The Box (with the Cover removed) is then attached to the
Mount using 4 Screws. The Amplifier, Power Supply or any other Equipment including the 1
Gang Receptacle are then installed inside the Box together with all relevant Cables. Attaching
the Cover completes the installation.

1. Surface Mount with (4) 8.32 Truss Head Screws
2. Plenum Box with Removable Cover with (6) 8.32 Truss Head Screws.
3. Single Gang Box with 2 Position Receptacle
4. (1) 10.32 x 5/8" Round Screw for Mounting Recepticle Box to Plenum Box
5 Receptacle Cover Plate

Access to the inside for Installation and Servicing is simple,
removing the 6 screws makes it very simple for a technician to
make adjustments at any time.

The Power Cable's Conduit attaches to the Plenum Box using a Standard Conduit Connector (Customer
Supplied), with the wires teminating directly to the Single Gang Receptacle Box inside.

OPTIONAL HANGING KIT Part # NB-PLHK

1. (4) 3/16.24 Eye Bolt with Nuts
2. (2) 5' Hanging Cable Sets UL & CSA Listed
3. 2 Gripples
4. 1 Hex Key

Nigel B Design, Inc. California, USA. Tel: (818) 487-9323 Fax: (818) 766-9805

Web Site: www.nigelbdesign.com. E-Mail: [email protected]

ADDITIONAL SIGNAL INLET/OUTLET PORTS

The amount of Power Outlets can be increased to

SIX

using up

to two 3 Position Taps.

Inside View showing a Nigel B

Amplifier & Power Supply fitted

REMOVABLE COVER

Additional Access Ports are provided in the Surface Mount for those occasions when access to and from
other equipment is required.

UP TO SIX POWER OUTLETS

FITTING THE HANGING KIT

The Installer attaches an Eye Bolt at each Corner. Each Pair of Hanging Wires simply Clips to each Eye
Bolt.

These Assemblies are UL & CSA Listed

and are rated at Maximum Load of 100 lbs. At the

Ceiling or Support End, the Cable is simply "looped through a "Gripple®". The Looped end is then

adjusted for the correct Length and Level, and the job is done.