Chapter 3. Specifications

34

LSI 3ware 9750 SATA+SAS RAID Controller Card Installation Guide

See Table 10 for a list of jumpers and connectors on the 9750-16i4e
RAID Controller Card. See Figure 5 for the 9750-16i4e controller
card layout.

Table 10: Jumpers and Connectors for 9750-16i4e

Jumper/

Connector

Type

Description

J1A2

Reserved for
LSI use.

4-pin connector.

Reserved for LSI use.

J1B1

LED fault
indication
connectors
for internal
drive ports
(Ports 8
through 15)

2x8-pin connector.

There is one LED connector for each
internal drive port. When lit the LED
indicates the corresponding drive has
failed or is in the unconfigured-bad state.

The LEDs function only in a direct-attach
configuration.

Drive attach is defined as a maximum of
one drive connected directly to each port
with no SAS expander.

J1B2

4 Lane
SATA+SAS
connector

(Ports 16-19)

SFF-8088 x4 external mini SAS
connector.

Connects the controller by cable to SAS
drives or SATA drives, or a SAS
expander.

J1B3

RAID key
connector

2-pin connector.

Enables support for RAID 5
configurations.

Jumper should not be present during
normal operation.

Advertising