.1.3.6.1.2.1.2.2.1.13.xxx – ifInDiscards
.1.3.6.1.2.1.2.2.1.14.xxx – ifInErrors
.1.3.6.1.2.1.2.2.1.15.xxx – ifInUnkownProtos
.1.3.6.1.2.1.2.2.1.16.xxx – ifOutOctets
.1.3.6.1.2.1.2.2.1.17.xxx – ifOutUcastPkts
.1.3.6.1.2.1.2.2.1.18.xxx – ifOutNUcastPkts
.1.3.6.1.2.1.2.2.1.19.xxx – ifOutDiscards
.1.3.6.1.2.1.2.2.1.20.xxx – ifOutErrors
.1.3.6.1.2.1.2.2.1.21.xxx – ifOutQLen
"xxx" means the interface identified by a particular value of this index is the same interface as
identified by the same value of OID 'ifIndex'.
absolute : Get the sample directly.
delta : Calculate the difference between samples (default).
<rising_threshold> : Rising threshold value (-2147483648–2147483647).
<rising_event_index> : Rising event index (1-65535).
<falling_threshold> : Falling threshold value (-2147483648–2147483647).
<falling_event_index>: Falling event index (1-65535).
rising : Trigger alarm when the first value is larger than the rising threshold.
falling : Trigger alarm when the first value is less than the falling threshold.
both : Trigger alarm when the first value is larger than the rising threshold or less than the falling
threshold (default)
Security Switch RMON Alarm Delete
Description:
Delete RMON Alarm entry. The entry index key is <alarm_id>.
Syntax:
Security Switch RMON Alarm Delete <alarm_id>
Parameters:
<alarm_id>: Alarm ID (1-65535).
Security Switch RMON Alarm Lookup
Description:
Show RMON Alarm entries.