Backplane Communication

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 176 of 259

ProSoft Technology, Inc.

June 23, 2011

The Modbus Pass-Thru block received from the module has the following
structure:

Offset

Description Type

Comments

0

Pass-Thru transaction
present

Input

1

Pass-Thru transaction
0-word/1-bit select

Input

2

Register Address

Input

3

Number of Registers

Input

4 to
126

Data.

Input

When word-swap (Supervisory output word 11) is
applied to a data packet containing an odd number of
words, the last word is swapped with a word of zero.
The Modbus protocol limits the packet to 125 words of
data; the extra word here allows for word-swap to be
applied to a 125-word data packet.

9.1.6 Modbus

Master

Block

The Modbus master block can be used by the processor to issue a Modbus
master command to a remote Modbus slave device. Configure Port 3 as a
Modbus master device. This block is optional, and must be defined only if the
application intends to use this feature.
The processor must set the following register from the Supervisory Output Block
to 1 in order to issue the Modbus master command to a remote Modbus slave:

Offset

Description Type

Comments

4

Issue Master Transaction

Signal

The Modbus master block configures the Modbus command to be sent to the
remote slave address.

Offset

Description Comments

0

Slave Address

1

Direction and register bank

2

Data Item Size and Swap Options

3

Register Address

4

Number of Data Items

5

Error Code

6 to 124

Data