General description (fig. 1), Important safety information, Warning – Philips DL8765/15 User Manual

Page 3

Advertising
background image

Symbol for indoor use only.

Symbol for 'Including RF transmitter'. This

means that this device emits non-ionizing

radiation. All devices with RF transmitters

or that use RF electromagnetic energy

must have a label with this symbol.

Indicates caution.The user should consult

the instructions for use for important

cautionary information such as warnings

and precautions that cannot, for a variety

of reasons, be presented on the medical

device itself.

Symbol for micro-USB connector.

Symbol for USB connector.

This symbol on the device means:

protected against access to hazardous

parts with a finger and against vertically

falling water drops when tilted up to 15

degrees.

–20ºC

60ºC

Indicates the storage and transportation

temperature limits to which the medical

device can be safely exposed: -20°C to

60°C.

Symbol for the 2 year Philips guarantee.

The Green Dot ('Der Grüne Punkt' in

German) is the license symbol of a

European network of industry-funded

systems for recycling the packaging

materials of consumer goods.

General description (Fig. 1)

1

Bluetooth® symbol

2 Battery symbol
3 Lock switch
4 Socket for micro USB plug
5 Blood pressure classification
6 Heart rate/irregular heart rate detector
7 Movement detector
8 User IDs
9 Cuff
10 On button
11 User ID button
12 Heart rate
13 Diastolic blood pressure
14 Inflation/deflation indicator
15 Systolic blood pressure
16 USB plug
17 Micro USB plug

Important safety information

Read this important information carefully before
you use the device and save it for future reference.

Warning

- Please keep the unit out of reach of infants,

children or pets, since inhalation or swallowing
of small parts can be dangerous or even fatal.

- The device is not suitable for measuring the

blood pressure of children.

- The device is not suitable for persons who have

electrical implants.

- Do not use this blood pressure monitor on any

arm where intravascular access or therapy
(such as an intravenous drip or a blood
transfusion), or an arterio-venous shunt (A-V
shunt) is present. The temporary interference to
blood flow by the blood pressure measurement
could result in injury.

- If you had a mastectomy (breast amputation)

do not use this blood pressure monitor on the
arm on the side of the mastectomy. The
inflating cuff can lead to pain, trauma and
further injury in the arm on the side of the
mastectomy.

- Consult your doctor if your suffer from illnesses

prior to using the device.

- No modifications of this equipment are allowed.

This may result in increased emissions or
decreased immunity of the device.

- Do not use the blood pressure monitor during

charging as it can cause injury.

- Do not touch the output of the adapter as it can

cause injury.

- Do not dispose of batteries in fire. Battery may

explode or leak.

- If you experience discomfort during a

measurement, such as pain in the arm or other
complaints, press the 'on' button to release the
air immediately from the cuff. Loosen the cuff
and remove it from your wrist.

- On the rare occasion of a fault causing the cuff

to remain fully inflated during measurement,
open the cuff immediately. Prolonged high
pressure (cuff pressure >300 mmHg or constant
pressure >15 mmHg for more than 3 minutes)
applied to the arm, may lead to bruises
(ecchymosis).

- Too frequent and consecutive measurements

could cause disturbances in blood circulation
and injuries.

- Beware of strangulation particularly for children

and infants due to cables.

- Do not connect the tube to other medical

equipment, as this could lead to dangerous
injuries.

- This device is not intended for patients outside

a home environment.

- Never use any accessories or parts from other

manufacturers or that Philips does not
specifically recommend. Using such accessories
or parts could cause a hazardous situation for
the user or damage to the device.

- Only use the accessories and detachable parts

authorized by the manufacturer. The use of
unauthorized parts or accessories may cause
damage to the device or injury to the user.

Advertising