Figure 4-2 DIP Switch

Binary 0011

Note

• The DIP switch No. 1 to 3 are suitable for setting the RS-485 communication address. No. 4 is for

Wiegand mode (OFF: Wiegand input, ON: Wiegand output).

• The DIP address cannot be repeated.

4.2 Install Secure Door Control Unit

Steps

1. Set the DIP of the secure door control unit according to the actual access control device

requirements.

Note

The DIP binary ranges from 0001 to 1111.

2. Drill holes on the wall or other places according to the mounting template.

Note

The minimum bearing weight of the wall or other places should be three times heavier than the

device weight.

3. Insert the provided plastic sleeve of the A4 expansion screw into the punched hole.

4. Insert the cable into the cable socket, and insert the Wiegand cable into the Wiegand interface.

Caution

If the cable needs to be connected from the side of the device, knock out the knockout hole on

one side.

5. Align the screw holes on both sides of the device with the sleeve in the wall and insert the

provided screws to fix the device.