en | Route Wires and Attach Connectors

Power Supply Units (AUTODOME7000, MIC7000

cameras)

2020-10 | |

Installation Manual

Bosch Security Systems, Inc.

4

Transformer

9

Earth-grounded conduit with power input
and earth-ground connection

5

Ethernet Wire

10

Earth-grounded conduit with Ethernet
video/control, audio input and output to
“head-end“ system

11

Earth-grounded conduit to camera

Method Two is to bypass the Power Supply Box and route the video, control, and alarm wires
directly to the Interface Board. You connect only the power wires inside the Power Supply
Box. All conduit and junction boxes used must be electrically earth-grounded.

GND TXD

RXD

C+

C-

GND TXD

RXD

C+

C-

P101

P106

P105

P1

0

7

XF

1

02

XF

1

0

3

XF

1

0

1

5

4

3

2

1

J1

03

J1

03

J1

03

J102

J101

(LED)

HTR DOME

(FUSE)

(FUSE)

(FUSE)

(FUSE)

BNC

J102

P10

7

P101

P102

P103

P104

P106

J101

AGND

A7
A6
A5
A4
A3

AGND
OUT 3
OUT 2
OUT 1

P105

LINE NC NEUT

Figure 7.2:

VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box Connected to Pipe Interface Board

VG4-A-PSU1/VG4-A-PSU2

Pipe Interface Board

1

120 VAC/230 VAC Power In

7

P101 Connector

2

P101 Connector

8

P107 Connector

3

Ground Connection

9

24 VAC Power In (to camera)

4

Transformer

10

Earth Ground

5

24 VAC Power Out

11

24 VAC Power In (to camera)

6

P107 Connector

12

24 VAC Power In (to Heater)

13

24 VAC Power In (to Heater)

14

Camera Power

15

Heater Power