Problem cause action required trouble shooting – Earlex HV7000A User Manual

Page 10

Advertising
background image

10

The paint drips

Paint too diluted

Add undiluted material

on item

Paint volume

Reduce the paint flow

being painted

too high

by turning Fluid Adjusting Screw

Moving too slowly

Increase speed of application

Spray gun trigger being

Release trigger earlier

held for too long

Spray gun too close

Increase the distance between

gun

and

workpiece

Paint is thin or

Paint too diluted

Add undiluted material

irregular

Paint volume

Increase the paint flow by turning

too low

Fluid Adjusting Screw

Moving too fast

Reduce speed of application

Spray gun clogged

Clean the gun

Spray gun too far away

Reduce the distance between

gun

and

work

piece

No spray pattern Paint too thick

Add thinner

being produced

Gun clogged

Clean the spray gun

Pick up pipe clogged

Clean Paint Feed Tube

Air hose split

Replace air hose

Gritty paint

Filter the paint

Container

almost

Refill

container

empty

Spray gun at an angle

Ensure Paint Feed Tube

is angled towards paint

Air intake

Check the condition of

blocked

the Filter and clean as neccessary

Unit will not

Circuit breaker tripped

Check the back of the unit. If the circuit

start

(HV7000 unit)

breaker has tripped, a white push button

indicator will appear. Push in to reset.

If this does not cure the problem, please

refer to your nearest service agent.

House circuit breaker

Check and reset if required.

PROBLEM CAUSE

ACTION

REQUIRED

TROUBLE SHOOTING

N0150 05/05.qxd 27/5/05 10:28 am Page 10

Advertising
This manual is related to the following products: