FCA Utilities Reference Manual

Page 16

Tests:

emlx_biu [pattern] - Performs the Bus Interface Unit test.
emlx_echo <did> [pattern] - Performs the ECHO test to a specified port id.
emlx_post - Performs the Power-On Self Tests.

Parameters:

pattern - 4 byte hex pattern to be used for test. (e.g. 0xA5A5A5A5)

Example:

emlxadm> diag emlx_biu

Result: EMLX_DIAG_BIU: Operation successful.

or

emlxadm> diag emlx_echo fffffc

Result: EMLX_DIAG_ECHO: Operation successful.

or

emlxadm> diag emlx_post

Result: EMLX_DIAG_POST: Operation successful.

Example:

emlxadm> diag code 0x4526

Result: CODE(0x4526): 16 (0x10)

ns

Performs and returns a complete query of the fabric name server.

Example:

emlxadm> ns

Nameserver:
-----------------------------------------------------------------
TYPE: 02
PID: 0113E1
WWPN: 21000020371938fa
PORT_NAME: (SEAGATE ST39103FC 0004)
WWNN: 20000020371938fa
NODE_NAME: (null)
IPA: ffffffffffffffff
IP_ADDR: 0.0.0.0
CLASS: 8
FC4_TYPES:
00000100,00000000,00000000,00000000,00000000,00000000,00000000,00000000

-----------------------------------------------------------------
TYPE: 02
PID: 0113E2
WWPN: 21000020371939a2
PORT_NAME: (SEAGATE ST39103FC 0004)
WWNN: 20000020371939a2
NODE_NAME: (null)
IPA: ffffffffffffffff
IP_ADDR: 0.0.0.0
CLASS: 8
FC4_TYPES:
00000100,00000000,00000000,00000000,00000000,00000000,00000000,00000000

Note: The return status from the HBA is displayed in decimal and hexadecimal if the

diagnostic code is valid for the HBA. No interpretation of the return status is provided.