Viewing port diagnostics – Emulex 375 User Manual

Page 59

Advertising
background image

E

MULEX

M

ODEL

375 SAN S

TORAGE

S

WITCH

U

SER

S

G

UIDE

C

HAPTER

3: S

WITCH

M

ANAGEMENT

E

MULEX

C

ORPORATION

56

P

ART

N

UMBER

00041369-002 R

EV

. B

Viewing Port Diagnostics

This page displays diagnostic information pertaining to each port in the switch. Use the information
provided on this page to diagnose abnormally high error counts on a particular port.

To view the current diagnostic settings:

Click Advanced Functions > Diagnostics > Port.

The Port Diagnostics page appears.

Statistic

Description

Port & Health

Color Indicators
• Green
• Yellow
• Red
See

“Port Utilization and Health” on page 52

for descriptions of the health

indicators.

Insertion Count

Number of times this port has been inserted into the network since the
switch was reset or the counters were cleared.

CRC Errors

Number of CRC errors that are detected in frames passing through this port
since the switch was reset or the counters were cleared.

Ordered Set Errors

Number of Ordered Sets that are received on this port with an encoding
error since the switch was reset or the counters were cleared.

Clock Delta

Difference (in parts per million) between the internal switch clock and the
received clock signal on the port.

State

Current state of this port – either inserted or bypassed

Beacon Port

Forces both port LEDs to flash on and off continuously. Use this to locate
and take action on a specific port. The flashing overrides normal port
indication until beaconing is turned off; however, port operation continues to
operate normally.

Figure 3-30: Port Diagnostics page

Advertising