The electronic board has the capability of memorizing
two different programmed temperature settings as fol-
lows (refer to Fig. 5):

For a pool, maximum 95°F (35°C)

For a spa, maximum 104°F (40°C)

To Select Pool or Spa Mode

To have access to either one of these programs, press
the SET key until you see P _S and by pressing the
UP or DOWN key you can switch to POL or SPA.

To Increase the Desired Water
Temperature (Pool or Spa Mode)

Push the SET key until you see POL or SPA. The pro-
grammed temperature will be displayed. Press the UP
arrow to increase the temperature setting one degree
at a time.

To Lower the Desired Water
Temperature (Pool or Spa Mode)

Push the SET key until you see POL or SPA. The pro-
grammed temperature will be displayed. Press the
DOWN arrow to decrease the temperature setting one
degree at a time.

Once the control has been programmed to the desired
pool water temperature, the programmed temperature
will be displayed for approximately 5 seconds. Then
the digital display will display the actual pool water
temperature.

To make the Board a Pool ONLY Board, call 800-
375-7378 for instructions.

To Select Temperature in °C or °F

Press the SET key until you see F _C. By pressing the
UP or DOWN key you can switch to °F or °C. Once the
temperature display mode has been programmed it
will be displayed for approximately 5 seconds, then
the digital display will return to the actual pool water
temperature in the mode that you have chosen.

System Start-Up

1. Verify that the Digital Board is displaying a temper-

ature and the pool pump is running and water is
circulating properly.

2. Verify that the Board is programmed so that the

desired temperature of the Pool and Spa is higher
than the displayed current water temperature.

3. Allow the heat pump pool heater to operate for a

few minutes to stabilize operating pressures and to
allow various component temperatures to normal-
ize.

4. Verify that the discharge air temperature is approx-

imately 8°–10°F cooler than the air entering the
unit. If not, see the Troubleshooting Section.

Seasonal Start-Up or Annual
Check

1. Remove leaves, pine needles, etc., from the evap-

orator coil. Clean the coil by gently applying a mild
solution of household liquid soap and water.

2. Gently rinse the coil with water; DO NOT use high

pressure.

3. Backwash or otherwise clean the pool filter. If nec-

essary, clean the skimmer basket and pump
strainer.

4. Set the valves to ensure proper water flow through

the unit.

NOTE: At the beginning of the heating season, or
whenever the pool water temperature is to be raised
several degrees, the pool pump and heat pump pool
heater may need to operate continuously for several
days. During summer months, only a few hours per
day may be necessary, or none at all.

NOTE: If the pool pump and heat pump pool heater
shut OFF before the water temperature is raised to
the desired level, you must lengthen the running time
of both. To do this, reset the time clock dial for the
longer running time, or manually operate the pump
with the timer override switch. Since the heat pump
pool heater capacity and efficiency are both greater
at higher ambient air temperatures, run time should
be set to take advantage of all daylight hours, when
the air is generally warmer.