background image

16

Plumbing Diagrams

Water In

(from pool

or spa)

Water Out

(to pool

or spa)

Filter

Fig. 6: For systems with pumps of less than 2 HP (under 80 gpm), no external

bypass is required. Connections are 2-inch unions. Plumb the heat

pump pool heater AFTER the filter and BEFORE any chlorinators.

Water In

(from pool

or spa)

Water Out

(to pool

or spa)

Filter

Fig. 7: For systems with pumps of 2 HP or greater (over 80 gpm), an external

bypass is required. Adjust the bypass valve to divert a minimum of 40

gpm through the heat pump pool heater. Connections are 2-inch unions. Plumb the

heat pump pool heater AFTER the filter and BEFORE any chlorinators.