Outside air kit, Recommended heights for flue pipe, Installation – Enviro Kodiak 1200 Fireplace Freestanding User Manual

Page 28

Advertising
background image

Installation

O

UTSIDE

A

IR

K

IT

:

It is mandatory to use outside air for installations in mobile homes.
A 4” (10.2 cm) fresh air adaptor kit is available. This adaptor can be

installed either on the back pedestal or through the floor under the

pedestal. The cover plate must be installed on the unit if your stove is

located in a mobile home or if using outside air from the bottom.
Place the 1⁄4” mesh screen between the fresh air adaptor and the body of

the pedestal (as shown to right).

NOTE: Fresh air connection to the unit must be a non-combustible pipe,

example: 4” (10.2 cm) single wall aluminum flex pipe.

NOTE: Remove the cover plate on the rear of the pedestal if room air is to be used for combustion air.

R

ECOMMENDED

H

EIGHTS

F

OR

F

LUE

P

IPE

:

The minimum flue pipe height at sea level is 12 feet (3.7 m) straight up from top of the unit. For every

1000 feet (305 m) above sea level, 4% could be added to the overall height. Use Tables 14, 15, and 16

to calculate the required vertical rise required.

Elevation

above sea

level

Minimum recommended flue pipe height for # of elbows

(Note: No more than 2 offsets (4 elbows) can be used. 2x45°=1x90°

feet

0

2 x 15° 4 x 15° 2 x 30° 4 x 30° 2 x 45° 4 x 45°

0-1000

12.0

12.7

13.3

13.3

14.7

14.0

16.0

1000-2000

12.5

13.2

13.8

13.8

15.3

14.6

16.6

2000-3000

13.0

13.7

14.4

14.4

15.9

15.1

17.3

3000-4000

13.4

14.2

14.9

14.9

16.5

15.7

17.9

4000-5000

13.9

14.7

15.4

15.4

17.1

16.2

18.6

5000-6000

14.4

15.2

16.0

16.0

17.6

16.8

19.2

6000-7000

14.9

15.7

16.5

16.5

18.2

17.4

19.8

7000-8000

15.4

16.3

17.0

17.0

18.8

17.9

20.5

8000-9000

15.8

16.8

17.6

17.6

19.4

18.5

21.1

9000-10000

16.3

17.3

18.1

18.1

20.0

19.0

21.8

meters

0

2 x 15° 4 x 15° 2 x 30° 4 x 30° 2 x 45° 4 x 45°

0-305

3.7

3.9

4.1

4.1

4.5

4.3

4.9

305-610

3.8

4.0

4.2

4.2

4.6

4.4

5.1

610-915

4.0

4.2

4.4

4.4

4.8

4.6

5.3

915-1220

4.1

4.3

4.6

4.6

5.0

4.8

5.5

1220-1525

4.2

4.5

4.7

4.7

5.2

4.9

5.7

1525-1830

4.4

4.6

4.9

4.9

5.4

5.1

5.9

1830-2135

4.5

4.8

5.0

5.0

5.5

5.3

6.0

2135-2440

4.7

4.9

5.2

5.2

5.7

5.5

6.2

2440-2745

4.8

5.1

5.4

5.4

5.9

5.6

6.4

2745-3050

5.0

5.3

5.5

5.5

6.1

5.8

6.6

���� �� ��������

Figure 25: Fresh Air Adaptor

onto the Back of the Pedestal.

Distance to add

Part used

feet

meters

45° elbow

1.0

0.3

90° elbow

2.0

0.6

“T”

3.0

0.9

1 foot

(0.3m) of

horizontal

run

2.0

0.6

Height

sea level with 2

x 30° elbows

13.3 ft (4.1 m)

one “T”

3.0 ft (0.9 m)

11⁄2 ft (0.6 m)

horizontal run

3.0 ft (0.9 m)

Total 1

19.3 ft (5.9 m)

4000-5000 ft

(1220-1525 m)

above sea level

13.9 ft (4.2 m)

one “T”

3.0 ft (0.9 m)

2 ft (0.6 m)

horizontal run

4.0 ft (1.2 m)

Total 2

20.9 ft (6.3 m)

Table 14: Recommended Height for Flue Pipe.

Table 15: Distance to add to

overall vertical height.

Table 16: Examples of calculating

overall vertical height required.

28

Advertising