EverFocus EDSR 110 User Manual

Page 29

Advertising
background image

19

Descriptions:

ALMINxx:

Alarm input xx (1~16)

GND:

common ground for alarm inputs

ALM_COMx: output relay x , contact root

ALM_NOx:

output relay x , NO contact

ALM_NCx:

output relay x , NC contact

ALMRST:

Alarm reset, control input for alarm reset, for dry NO contact towards GND

DISKFULL: OC output contact for signal HDD full, switches to GND

REC_IN:

Control contact for recording start

SPARE_IN / OUT: System error output. TTL-level 5VDC indicates "System Okay" status. The
contact will switch to open state, if one (ore more) of below listed events appears:

a) HDD full (If overwrite mode in RECORD menu is set to STOP)
b) No HDD
c) Over-temperature HDD
d) Power Loss
e) Cooler fan fault
f) Video Loss
g) Record off

Output level:
HIGH (5 V DC): System okay
Open state: System error