Power cord set requirements – Enterasys Networks VH-4802 User Manual

Page 44

Advertising
background image

30 Technical Specifications

VH-4802

MDI/MDI-X Crossover Cable Wiring

Figure A-1 shows the wiring scheme for implementing a crossover cable

if needed for connection to the switch’s 10Base-T or 100Base-TX ports.

Such a cable may be required when connecting the switch to another

switch or a hub device.

Figure A-1. External Crossover Cable Wiring

Power Cord Set Requirements

The wide-range input feature of the VH-4802 Ethernet switch permits it to

operate from any line voltage between 100 and 240 VAC.

The power cord set (appliance coupler, flexible cord, and wall plug) you

received with the switch meets the requirements for use in the country

where you purchased the switch.

Power cord sets for use in other countries must meet the requirements of

the country where you use the switch. For more information on power

cord set requirements, contact your Enterasys Networks Support

Representative.

General Requirements

The requirements listed below are applicable to all countries:

The length of the power cord set must be at least 5.00 feet (1.5 m)

and a maximum of 6.56 feet (2.0 m).

All power cord sets must be approved by an acceptable accredited

agency responsible for evaluation in the country where the power

cord set will be used.

The power cord set must have a minimum current capacity of 10A

and a nominal voltage rating of 125 or 250 VAC, as required by each

country’s power system.

The appliance coupler must meet the mechanical configuration of an

EN 60 320/IEC 320 Standard Sheet

C13 connector for mating with

appliance inlet on the hub.

ELS100-48tx2m.book Page 30 Thursday, November 16, 2000 4:59 PM

Advertising