INSTALLATION:


THIS UNIT HAS BEEN DESIGNED TO BE INSTALLED IN MANY LOCATIONS. BECAUSE THIS UNIT IS A ZERO
CLEARANCE FIREPLACE IT MAY BE INSTALLED IN A WOOD FRAMED COMBUSTIBLE CHASE, AS SHOWN.


FRAMING DIMENSIONS:

WIDTH:

35 3/8” (89.85 CM)

HEIGHT:

31 3/4” (80.65 CM)

(INCLUDING FINISHED HEARTH HEIGHT)
DEPTH:

13 3/4” (34.93 CM)

NOTE:

When preparing framing for this unit insure that the

framing on the outside wall or ceiling will not interfere with
the vent pipe. Framing must maintain proper clearances to
the unit and vent pipe.

NOTE:

Also make sure that the top header above the framing
opening is installed on the edge or upright, this will maintain
proper clearances to the vent pipe.








NOTE:

MAKE SURE THAT THE UNIT HAS BEEN INSTALLED SO

THAT THE BOTTOM OF THE UNIT IS INSTALLED AT THE
SAME HEIGHT AS THE FINISHED HEARTH HEIGHT. IF
THE UNIT IS NOT INSTALLED IN THIS MANNER THE
SURROUND WILL NO LONGER FIT ONTO THE UNIT.










Once the framing has been completed remove the unit from
its packaging and remove the top louvers and door cover by
lifting up on the louvers and door cover and pulling outwards
from the unit.

Remove the decorative surround panel from the unit. There
are four screws located in the four outer corners just inside
the surround panel. (AS SHOWN on next page)