IPI 100 Series, IPI 200 Series • Programming and Control

IPI 201/204 SIS

Programming, cont’d

5-8

X4^

= E-mail recipient’s address (e.g.,

[email protected]

) for the person to whom messages will be sent.

The e-mail address has a 31-character maximum.

X4&

= Name (numeral) of e-mail file to be sent

X4(

= Default name: a combination of the model name and the last 3 pairs of

the IPI 200 series’ MAC address

X5@

= Connection’s security level

11 = user

12 = administrator

X6#

= Pulse time in 20 ms per count. If this parameter is missing or = 0, then

pulse length = default = 25 = 500 ms. 1 = 20 ms (minimum pulse

time) to 65535 = 1310700 ms (maximum pulse time).

X6(

= IP connection timeout period in seconds. Each step is specified in 10-

second intervals (1 - 65000, default = 30 = 300 seconds). If no data

is received during the specified period, the Ethernet connection

closes. Responses are returned with leading zeros.

X7)

= The number to insert into an email message if a ____.eml file has an

embedded server-side include “<!--#echo var = “WCR

|

” -->”

(the

E

CR

}

command with no parameters.) The numeral is a

16-bit number to be employed as the user defines.

This is an optional parameter. Use 0 as a placeholder if the
optional

X4&

variable is used but

X7)

is not needed. Maximum

= 65535.

X7!

= Hardware (MAC) address: 4 most-significant hex nibbles converted

into single 16-bit decimal number.

X7@

= Hardware (MAC) address: 8 least significant hex nibbles converted

into single 32-bit decimal number.

N

This could be as large as 10 digits!).

X7#

= An e-mail account username of up to 31 characters. Do not use

commas. This parameter is optional during setup and is used for

SMTP authentication.

X7$

= An e-mail account password (for SMTP authentication) of up to 31

characters. Do not use commas. This parameter is optional

during setup.

X20^

= Voltage (in volts)

X20&

= Temperature in degrees Celsius (the response is 3 digits including

leading zeros)

X20(

= Front panel lockout (executive mode) status

0 = off/unlocked (default)

1 = on, disable/lock the front panel

X21&

= Firmware’s event status polling period from 0 to 255 in 20 ms

increments.

X21&

is optional: if it is not set, it defaults to 100

(2 seconds) and is not shown in the command’s response. If

X21&

is set to 0, the firmware does not poll for event status.

N

The event number that is polled is set by

X3%

in the EN

command.