Mon Day, DD Mon YYYY HH:MM:SS
(c)Copyright 2007, Extron Electronics, IPI 204, V1.00, 60-810-00

]

Mon Day, DD Mon YYYY HH:MM:SS
Vx.xx is the firmware version number.

The IPI sends the boot and copyright messages under the

following circumstances:
• If the IPI is off and an RS-232 connection is already set up

(the PC is cabled to the IPI 204 series and a serial terminal

emulation program such as HyperTerminal is open), the

connected unit sends these messages via RS-232 when it is

first powered on.

• If the IPI is on, it sends the boot and copyright messages

when you first open a Telnet connection to the IPI. You

can see the day of the week, date, and time if the IPI is

connected via Telnet, but not via RS-232. If you are using a

Telnet connection, the copyright message, date, and time are

followed by a password prompt.

Additional messages may be sent by the IPI in response to front

panel selections and volume adjustments and when scripts are

executed during scheduled events.

Password information

The “

]

Password:” prompt requires a password (administrator

level or user level) followed by a carriage return. The prompt is

repeated if the correct password is not entered.
If the correct password is entered, the unit responds with

]

Login Administrator

]

” or “

]

Login User

]

”, depending

on the password entered. If passwords are the same for both

administrator and user, the unit will default to administrator

privileges.

Error responses

When the IPI receives a valid SIS command, it executes the

command and sends a response to the host device. If the IPI is

unable to execute the command because the command is invalid

or it contains invalid parameters, it returns an error response to

the host.
The error response codes and their descriptions are as follows:
E12 – Invalid port number

E13 – Invalid value (the number is out of range/too large)

E14 – Not valid for this configuration