Cd5220 customer display, Interface specifications 4.1 – Epson CD5220 User Manual

Page 7

Advertising
background image

CD5220 customer display

4. INTERFACE SPECIFICATIONS

4.1

Communication

4.1.1 Serial port (RS232C) communication

(a) The interface specification are based on EIA RS232C baud rate 9600 or

4800 bps ( select by DIP switch, refer Table 4-7) 8 data bits, none parity, 1

or more stop bits

(b) Serial port (RS232C) communication flow

1. Data flow : PC/host to display, display to printer, printer to

PC/host

2. Control flow : display to PC/host, printer to display, PC/host to

printer

(c) CD5220/CD6220 will inactive DTR or RTS signal to PC/host, the

following two condition.

1. Printer inactive DTR or RTS signal.

2. The pass through buffer in CD5220/CD6220 is full ( 200bytes ) .

* If PC/host keep transmitting the data to printer when CD5220/CD6220

inactive DTR or RTS , data will be lost.

4.1.2 Parallel port (Centronic) communication

(a) data flow : PC/Host to display, display to printer

(b) control flow : printer to display , display to PC/Host

(c) When data has been transmitted to printer by parallel port interface, the

CD5220/CD6220 response the printer status to PC/Host, When printer

active the BUSY signal, CD5220/CD6220 will keep accept the data until the

Advertising