Electrolux U30306 EFC650-950 User Manual

Page 45

Advertising
background image

45

S

9S

2

1

6

6

4

7

5

8

12

13

13

14

15

15

4

4

11

9S

9S

9K

9K

9K

9K

4

Ø 120mm

10S

14

7

K

9K

9K

6

6

7

7

3

3

Wall unit mounting - Fig. 6

• Put the template onto the wall (1) and drill two Ø12mm holes (2).

• Fit two hooks (3) on the drilled holes.

• Remove the metal filters (4) and hang the hood on the hooks and adjust the position of the hood using the two

screws on the bottom of the hooks (5).

• Depending on the model, mark 2 or 4 points (6). Remove the hood and drill 2 or 4 Ø8mm holes on the marked

points. Fit 2 or 4 Ø8mm wall dowels, Hang again the hood and fix the hood permanently with 2 or 4 screws

5X45 (7).

• Fix the chimney support (8) with two screws 5 x 45 mm and two wall dowels on the wall close to the ceiling.

• For the extraction version: Fit the connection ring (S) on the top of the hood with two screws Ø 3,5 x 6,5

mm (9S) then fit a vent hose long enough to reach the outside (10S).

For the recirculation version: Fix definitively the deflector (K) on the top of the hood with two screws Ø

3,5 x 6,5 mm (9K).

• Prepare the electric connection (11) (see relative chapter).

• Fit the chimney (12) and fix it on the chimney support with two screws 3 x 9 mm (13).

The lower part of the chimney must be slid down and inserted on the housing on the upper part of the hood

(14).

• Fit the two grids (15) on both sides

of the chimney.

Fig. 6