Hardware setup, cont’d, Mlc 104 ip plus • hardware setup, 4 mlc 104 ip plus • hardware setup – Epson MediaLink Controller MLC 104 IP Plus User Manual

Page 10: An equivalent digital i/o port circuit

Advertising
background image

MLC 104 IP Plus • Hardware Setup

Hardware Setup, cont’d

2-4

MLC 104 IP Plus • Hardware Setup

2-5

MLC 104 IP Plus

Right Side Panel

COMM LINK

A B C D E

+V OUT

GR

OUND

CM

IR IN

SCP

E

C

B

A

SCP communication (IR)

Ground ( )

IRCM, ACM, RCM, CM

+12 VDC

C

B

A

Maximum =
2 SCPs
Per System

Maximum =
4 Control
Modules
(4 module
addresses)

Ground ( )

+12 VDC

Ground ( ) & Drain Wire

E
C

B

A

SCP Communication
Control Module Communication

+12 VDC

= White

= Black & Drain Wire

= Violet

= Red

IRCM, ACM, RCM, CM

DVD & VCR CONTROL

PLAY NEXT/FWD PAUSE

STOP

TUNER

Tx

PREV/REW

ENTER

TITLE

MENU

TV/VCR

DVD

VCR

SCP 104

IRCM-DV+

CONFIG

DISPLAY

VOLUME

SCP 104

ON

PC

VCR

DVD

OFF

1

2

3

4

200' (61 m) max.

to Last Device

Extron CTLP Cable Color Code:

An MLC 104 IP Plus controller daisy chained to a
SCP 104 remote panel

N

The maximum distance allowed between an MLC

controller and a SCP 104 is 200’ (61 m).

c

Digital I/O — This port is configurable as a digital input or

digital output and can be used to connect a variety of devices,

such as sensors, switches, LEDs, and relays.

You can connect the Extron IPA T RLY4 to the MLC to enable a

relay function (to raise a projector screen, for example). To use

the IPA T RLY4 with the MLC 104 IP Plus, do the following:
1.

Use Global Configurator to set the MLC's digital I/O ports

to output mode.

N

Refer to the

MLC 104 IP Plus User's Manual for the

steps to set this port to output.

When the MLC's output signal is applied to one of the

IPA T RLY4's relays, that relay’s NO (normally open)

contacts close and its NC (normally closed) contacts open.

2.

Connect the MLC's 12 VDC output to the IPA T RLY4's "C"

(common voltage) terminal.

3.

Connect the MLC 104 IP Plus' digital I/O wires (from

digital I/O ports 1, 2, and 3) to the IPA T RLY4's inputs

(1, 2, and 3), as shown below. The Extron Comm-Link

(CTL and CTLP) cable is recommended for these

connections.

1
2
3

GROUND

+12V OUT

CM

GROUND

IR OUT

GROUND

SCP

GROUND

Tx
Rx

DISPLA

Y

RS-232/IR

A B C D

E

COMM LINK

LAN

PRESS

TA

B

WITH

TWEEKER

TO

REMO

VE

A

B

MLS

RS-23

2

PO

WER

12V

DIGI
TA

L

I/O

IR IN

Tx

GROUND

Rx

+12V IN

IP

A

T RL

Y4

1 2 3 4

C

INPUTS

MLC 104 IP Plus
Right Side

IPA T RLY4
Front Panel

Relay 1

Relay 2

Relay 3

+12 VDC

N

Refer to the

IPA T RLY4 User's Guide for information on

how to wire the IPA T RLY4's relay outputs.

As shown in the illustration below, the digital I/O port is set to

measure two states: on or off; high or low. Its input threshold

voltages are as follows: low is <2.0 V and high is >2.8 V.

24K

SW1

2K

+12V

+5V

SW2

I/O

GND

An equivalent digital I/O port circuit

Advertising