background image

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Ph.

+353 61 471277

Fx.

+353 61 471053

Email.

[email protected]

Web:

www.eielectronics.com

E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice

.

Ei205EN DataSht RevB


Model

Ei205EN CO Alarm

Installation & Placement

To mount onto a wall or ceiling, simple remove the battery compartment and mark the position of the two mounting holes.
Drill two holes using a 6mm drill for the plastic plugs (supplied) and screw the unit home with the screws supplied

If locating the CO alarm in a room with an appliance

-

the alarm should be located between 1m and 3m horizontally from the appliance and between 1.85m and 3m from the
appliance

-

the alarm should be located preferably on the ceiling, at least 300mm from any wall

-

if placed on a wall, the CO alarm should be as ahigh as possible but not within 150mm of the ceiling


If locating the CO alarm in a room remote from the appliance

-

the alarm should be located at a level similar to the breathing zone of the occupant (typically 1.5m to 2m above floor
level and in bedrooms at the height of the bed)


More specific details are found in the Use & Care Instruction Booklet.

Technical Specification

Sensor

Electrochemical sensor


Sensitivity:

Meets BS EN 50291:2001

Button Test:

Checks the electronics and horn


Memory Feature

When the test button is pressed
the horn will sound and the red
light will only flash if the unit has
previously detected CO and been
in alarm

Automatic Self-Test:

Horn beep and amber fault light

flashes every minute if a fault is
found

Supply Voltage:

3 x 1.5V AA Alkaline battery

Dimensions:

135 x 105 x 71 mm

Weight:

260g



Power-On Indicator:

Flashing green LED every minute


Alarm:

Electronic Piezoelectric horn


Alarm Sound Output:

85dB (minimum) at 3m


Alarm Status:

Red LED flashes and horn sounds


Temperature Range:

-5

o

to 40

o

C


Humidity Range:

15% to 95% Relative Humidity

Interconnect:

Up to 12 detectors with Ei205C EN
model only

Fixing:

Simple screw fixings

Plastic material:

UL94VO flame retardant


Warranty:

2 year warranty


Approvals:

Kitemarked to BS EN 50291:2001


Specifications are subject to change