1. Drill holes at marked locations using 5/16” drill

bit. For solid walls (concrete or masonry), drill

at least 1” deep.

2. Fold wall anchor as shown in figure 8 below.

Figure 8.

3. Insert wall anchor (wings first) into hole. Tap

anchor flush to wall.

4. For thin walls (1/2” or less) insert red key into

wall anchor.

5. Place mounting bracket onto wall. Line up

holes on each end of bracket with wall anchors.

6. Insert mounting screws through bracket and

into wall anchors.

7. Tighten screws until mounting bracket is firmly

fastened to wall.

Placing Heater on Mounting Bracket

1. Locate two horizontal slots on back pane of

heater (see figure 19).

2. Place heater onto mounting bracket. Slide hori-

zontal slots onto stand-out tabs on mounting

bracket.

Figure 9

Installing Bottom Mounting Screws

1. Locate two bottom mounting holes. These

holes are near bottom on back panel of heater

(see figure 10).

Figure 10

2. Mark screws locations on wall.
3. Remove heater from mounting bracket.
4. If installing bottom mounting screw into hollow

or solid wall, install wall anchors. Follow steps 1

through 4 under Attaching to Wall using Anchor.

If installing bottom mounting screw into wall

stud, drill holes at marked locations using 9/64”

drill bit.

5. Re-place heater onto mounting bracket.
6. Place spacers between bottom mounting holes

and wall anchor or drilled hole.

7. Hold spacer in place with one hand. With the

other hand, insert mounting screw through

bottom mounting hole and spacer. Place tip of

screw in opening of wall anchor or drilled hole.

8. Tighten both screws until heater is firmly se-

cured to wall. Do not over tighten.

Note: Do not re-place front panel at this time. Re-

place front panel after making gas connections and

checking for leaks.

FLOOR MOUNTING AWAY FROM WALL:

Figure 11

Installing Support Feet (see figure 11)

1. Lay heater onto table on its back with bottom

edge overhanging table edge.

2. Securely attach feet to bottom of heater using

2 – self-tapping screws each.

Note: Feet should have long end going out the

front of heater, and the edge coinciding with side of

heater. If feet overhang side of the heater, switch

leg location.
3. Place heater on non-combustible surface (see

Locating Heater above) before proceeding with

gas connection. If this will be a permanent loca-

tion, heater may be locked into position using

anchoring holes in mounting feet.

Note: Use of floor mounting feet will require you to

use a 3/8 NPT street elbow to make gas connec-

tion.

CONNECTING TO GAS SUPPLY

WARNING: A qualified service person must con-

nect heater to gas supply. Follow all local codes.
WARNING: This appliance requires a 3/8” NPT