Enerco HSIR30LPT User Manual

Page 9

Advertising
background image

9

Installation Instructions and Owner’s Manual

Unvented Liquid Propane Fired Room Heater

Pressure Testing Heater Gas Connections:

1. Make sure that the heater supply piping sys-

tem is connected and has been leak tested as

described above.

2. Make sure control knob of heater is in OFF

position.

3. Open equipment shutoff valve (see figure 13).
4. Open propane/LP supply valve.
5. Check all joints from equipment shutoff valve

to control valve (see figure 14). Apply mixture

of liquid soap and water to gas joints. Bubbles

forming show a leak.

6. Correct all leaks at once.
7. Light heater (see Operating Your Heater, pages

11 and 12 for thermostat models or pages 9

and 10 for non-thermostat models). Check the

rest of the internal joints for leaks.

8. Turn off heater (see To Turn OFF Gas to Appli-

ance, page 12 for thermostat models and page

11 for non-thermostat models).

9. Replace lower front panel.

Figure 13
Figure 14

ELECTRICAL WIRING DIAGRAM:

Figure 15

If any original wiring as supplied with the heater must

be replaced, it must be replaced with type AWG 105

o

C

wire or its equivalent except as indicated.

WARNING: Electrical Grounding Instructions: This

heater is equipped with a three-prong (grounding)

plug for your protection against shock hazard and

should be plugged into a properly grounded three-

prong receptacle.

OPERATING YOUR HEATER

NON-THERMOSTAT MODELS
IR10LP / BF10LP
FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-

erty damage, personal injury or loss of life.
A. This appliance has a pilot that must be lighted

by hand. When lighting the pilot, follow these

instructions exactly.

B. BEFORE LIGHTING smell all around the appli-

ance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and

will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use

any phone in your building.

Immediately call you gas supplier from a neigh-

bor’s phone. Follow the gas supplier’s instruc-

tions.

If you can not reach your gas supplier, call the

fire department.

Equipment

Shutoff Valve

Open

Closed

Gas Meter

Control Valve

Equipment

Shutoff Valve

Advertising