Setting up optimal audio gain, Installation, cont’d – Extron electronic MLS 103 V User Manual

Page 10

Advertising
background image

MediaLink VersaTools Switchers • Installation

MediaLink VersaTools Switchers • Installation

Installation, cont’d

Control and power connections

11

MLC/RS-232 Power port (all models)

— An Extron MediaLink

Controller (MLC 206), a computer, or a third party RS-232
controller provides remote control of input switching and
volume, and also provides a way to set the switcher’s audio
input levels. To control and/or set up the MLS, connect a cable
between this 5-pole 3.5 mm captive screw connector and an
optional MLC 206, computer, or a third party RS-232 controller.
Also connect an external 12VDC power supply here to provide
power to the MLS and to the optional MLC.

Extron Comm-Link cable is recommended for this connection.
If you use Comm-Link cable, the switcher and controller can be
up to 250 feet (76.2 m) apart. Wire the captive screw connector
for connection to either an MLC 206 or third party controller as
shown in the picture on the next page.

For a stand-alone MLS switcher, connect a cable from the host
computer or a third party control system to this connector to set
up and remotely control the switcher, connect a 12VDC power
supply, and tie all the drain wires to the same ground.

For an MLS switcher slaved to an MLC controller, connect a
cable from the MLC’s MLS/Power port and from a 12VDC
power supply, and tie all the drain wires to the same ground.

MLC/RS-232

POWER

A B

MLS100Series
Switcher
MLC/RS-232
Power Port

A B C D E

A B C

IR

Display/Source Control

Extron Switcher Control

Relays

IR / RCM

RS-232

D E

A B C

A B

D

1A 1B 2A 2B 3A 3B

1 2 3 4 5 6

Tally Out

MLS/Power

33-644-01 A

07 01

Pr
inted in the

USA

MLC 206 Bottom Panel

MLS 103 V
Rear Panel

3

1

2

OUTPUT

INPUTS

MLS 103 V

L

R

A B

L

R

L

R

L

R

1

2

3

L

R

4

AUX/MIX

MONO

AUDIO INPUTS

OUT

CONTROL/

POWER

12V .5A MAX

Ground ( )

+12VDC input

+12VDC

Ground ( )

Transmit (Tx)

B

Receive (Rx)

A

Transmit (Tx)
Receive (Rx)

B
A

Connecting an MLC 206
to a MediaLink VersaTools Switcher
and an external power supply

NOTE

You must connect a
ground wire between
the MLC and MLS.

MLC 206's
MLS/Power
Port

NOTE

If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.

A B

MLS / Power

Ground all devices

External

Power Supply

(12VDC, 1A max.)

External

Power Supply

250 ft

(76.2 m)

max.

Setting Up Optimal Audio Gain

Audio input levels and desired output levels vary depending on
the types of equipment involved. Before setting the MLS’s per-
input gain or attenuation, determine the levels of the input and
output equipment. Use the table below as a general guide.

Typical Audio Levels for Various Equipment Types

Input/Output Levels

X

X

Professional line level audio equipment

X

X

+4dBu 0dBu -10dBV

(-8dBu)

-20dBV

(-18dBu)

Equipment

Categories

Consumer audio equipment (VCRs, DVDs,

laptop computers, portable audio devices)

Once the system has been cabled and set up via the control
software and the front panel Aux/Mix adjustment, the MLC or
a host computer communicating through the MLC can be used
to remotely control the switcher. Refer to chapter four of the
MediaLink Controllers User’s Manual and to the MediaLink
Control Program help file for details on configuring an
MLC-MLS system.

An Extron IR Link infrared repeater cannot be used with
the MLS 100 Series switchers. There is no connection
for that device’s control signals.

The MLC to which the MLS 100 Series switcher is
connected must have MLC firmware version 1.04 or
higher

. The control/setup software must be version

2.0 or higher

. Use one of the following methods to find

out the version levels of the MLC’s firmware and the
control software.
• Connect the MLC’s RS-232 port to a computer or

RS-232 controller, and send an SIS command (see
chapter four) of
Q to the MLC. The MLC will respond
with its firmware version.

• Connect the MLC’s RS-232 port to a computer, start

the MediaLink control software
(see chapter four), and click on
Help to display the software
version, the MLC’s firmware
version, and the MLS’s
firmware version as shown in
the example at right.

If your MLS’s firmware is an earlier version, contact
Extron to obtain updated firmware.

2-9

2-8

Advertising
This manual is related to the following products: