To Replace or Clean Check Valve

1. Release all air pressure from air tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug outfit.
3. Loosen the nut on the outlet tube

and move the outlet tube to the
side.

4. Unscrew the check valve (turn

counterclockwise) using a socket
wrench.

5. Make sure the valve disc moves

freely inside the check valve and
the spring holds the disc in the
upper, closed position. The check
valve may be cleaned with a
solvent, such as paint and

varnish remover.

6. Apply sealant to the check valve

threads. Reinstall the check valve
(turn clockwise).

7. Replace the outlet tube and tighten

the nut.

8. Perform the Break-in Procedure.

See "Break-in Procedure" in the Operation section.

15- ENG

A08591

Unit cycles automatically when power is on. When doing
Maintenance, you may be exposed to voltage sources,

compressed air or moving parts. Personal injuries can occur. Before
performing any Maintenance or repair, unplug the compressor and bleed
off all air pressure.

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.

Outlet Tube

Check
Valve

Nut

Before servicing:

• Unplug or disconnect electrical supply to the air compressor.

• Bleed tank of pressure.

• Allow the air compressor to cool.

SERVICE AND ADJUSTMENTS