Troubleshooting – Encore electronic (66-501-1) User Manual

Page 17

Advertising
background image

17- ENG

A08591

Performing repairs may expose voltage sources, moving

parts or compressed air sources, moving parts or

compressed air sources. Personal injury may occur. Prior to attempting

any repairs, unplug the air compressor and bleed off all air tank air

pressure.

PROBLEM

CAUSE

CORRECTION

Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.

Pressure switch "cut-out"
too high.

Move On/Auto/Off lever
to the "OFF" position, if
the outfit does not shut off
contact a Trained Service
Technician.

Contact a Trained Service
Technician.

Excessive tank
pressure - safety
valve pops off.

Tube fittings are not tight
enough.

Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution.

Do Not

Overtighten.

Air leaks at
fittings.

Air leaks at
pressure switch
release valve.
(if equipped)

Defective pressure switch
release valve.

Contact a Trained Service
Technician.

Air leaks in air
tank or at air
tank welds.

Defective air tank.

Air tank must be replaced.
Do not repair the leak.

Do not

drill into,

weld or otherwise modify

air tank or it will weaken.

The tank can rupture or

explode.

Air leaks
between head
and valve plate.

Leaking seal.

Contact a Trained Service
Technician.

Possible defect in safety
valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Air leak from
safety valve.

Possible defect in safety
valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Knocking Noise.

TROUBLESHOOTING

Advertising