CONVENTIONAL MODE OPERATION

The procedures in the following section describes Conven-
tional Mode operation. Each conventional channel may be
programmed with one or more features such as Channel Guard
or telephone interconnect capability. Follow these procedures
if operating in a conventional system.

RECEIVING A MESSAGE

1.

Turn the radio on by sliding the ON/OFF switch on the battery pack, to
the ON position. A yellow area will be visible on the battery. After the
radio has passed the power-up self test an optional tone will sound and
the current System and Group/Channel will be displayed. If the unit
does not pass the test, the display will be blank.

2.

Press the SHIFT/CLR button and then use the SELECT buttons

I or

J to select a Conventional system. The SYStem display will indicate
the current System selected.

3.

Use the SELECT buttons

I or J to select the desired Channel. The

GRP icon will be surpressed but the field will still display the channel.
The radio is now ready to receive messages.

4.

Press the SHIFT/CLR button twice ("double click") to disable squelch
and monitor the channel. Adjust the VOLUME buttons to the desired
audio level.

5.

When a message is received (and the correct Channel Guard signal
is decoded, if programmed and enabled) the receiver will unsquelch
and the message will be heard.

57

Advertising