OPERATING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.


A) This appliance is equipped with a pilot, which must be lit by

hand by following these instructions exactly.

B) BEFORE LIGHTING smell all around the appliance area

for gas, and next to the floor because some gas is heavier
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s

phone. follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

C) Use only your hand to push in or turn the gas control

knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it . Call a qualified service
technician. Force or attempted repair may result in a fire
or explosion.

D) Do not use this appliance if any part has been under

water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the
control system and any gas control which has been under
water

LIGHTING INSTRUCTIONS


1. STOP! Read the safety information above.
2. Turn off all electrical power to the appliance.

3. Turn the gas control knob clockwise

to

the “off’ position.

4. Open

door.

Wait five (5) minutes to clear out any gas.

Close door. If you smell gas including near the floor,
STOP! Follow “B” in the above safety information.
If you don’t smell gas go to next step.

5. Find the pilot located to the right between the front and

rear burner.

6. Turn gas control knob counter-

clockwise to “PILOT”.

7. Push the gas control knob in fully and hold. Immediately

light the pilot by pushing the piezo spark igniter. Keep
knob depressed for about 30 seconds after pilot is lit.
Release knob. If pilot goes out, repeat steps 4 through 6.

WARNING The gas valve has a lockout device, which will not

allow the pilot burner to be re-lit until the thermocouple,
has cooled.

If the knob does not pop up when released, stop and

immediately call your service technician or gas supplier.

NOTE: Check to be sure the pilot flame engulfs the

thermocouple and that the burners light completely.

If the pilot will not stay
lit after several tries,
turn the gas control
knob to “OFF" and
call you service
technician or gas
supplier.



8. Turn gas control knob counter-clockwise

to the “ON” position.
Flip burner switch to “ON” then turn “HI / LO” knob to the
desired setting.

HI \ LO knob

Control knob


9. Turn on all electrical power to the unit

TO TURN OFF GAS TO

APPLIANCE

Turn the gas control knob clockwise to “OFF” DO

NOT FORCE

1. Turn off all electrical power to the appliance if service is to be performed.
2. Flip burner switch to off.








9