4 emergency stop – Epson G10 Series User Manual

Page 16

Advertising
background image

Setup & Operation 1. Safety

6

G10 / G20 Rev.2

1.4 Emergency Stop

If the Manipulator moves abnormally during operation, immediately press the Emergency
Stop switch. Stops the power supply to the motor, and the arm stops in the shortest
distance with the dynamic brake and mechanical brake.

However, avoid pressing the Emergency Stop switch unnecessarily while the Manipulator
is running normally. Otherwise, the Manipulator may hit the peripheral equipment since
the operating trajectory while the robot system stops is different from that in normal
operation.
To place the system in emergency mode during normal operation, press the Emergency
Stop switch when the Manipulator is not moving.
Refer to the Controller manual for instructions on how to wire the Emergency Stop switch
circuit.

Free running distance in emergency

The operating Manipulator cannot stop immediately after the Emergency Stop switch is
pressed.
The free running time/angle/distance of the Manipulator are shown below. However,
remember that the values vary depending on following conditions.

Weight of the end effector

Weight of work piece

Operating pose

Weight Speed

Accel

etc.

Conditions for Measurement

G10

G20

Accel Setting

100

100

Speed Setting

100

100

Load [kg]

10

20

Weight Setting

10

20

Joint #1

Start point of
operation

Target point

Stop point

Joint #2

Point where the
emergency stop
signal is input

Controller RC180
Manipulator G10-85***

G20-A0***

Joint #1 + Joint #2

[sec.]

0.7

1.3

Free running
time

Joint #3

[sec.]

0.5

0.8

Joint #1

[deg.]

70

110

Joint #2

[deg.]

50

50

Free running
angle

Joint #1 + Joint #2

[deg.]

120

160

Free running
distance

Joint #3 G10/G20-**1**[mm]
G10/G20-**4**

80

160

90

170

Contact us for details of G10-65*** or G20-85***.