Notes for Test Institutes

Testing in accordance with EN 60704 must be carried out with the
appliance fully loaded and using the test programme (see Programme
Table).

Tests in accordance with EN 50242 must be carried out when the salt
dispenser and rinse aid container have been filled with salt and rinse
aid respectively and using the test programme (see Programme Table).

Sample loading arrangements:
Upper basket

Lower basket with cutlery basket

Cutlery basket

Full Load:
12 place settings
incl. serving dishes

Half Load:
6 place settings incl. serving, leaving
alternate positions free

Detergent Dosing:

5g + 25g (Type B)

20g (Type B)

Rinse Aid Setting:

4 (Type III)

4 (Type III)