De-rating for High Altitude

For U.S. installations, the Clarity Direct Vent is approved for elevations up to 2000 feet using the factory-installed burner

injectors. At elevations above 2000 feet, U.S. codes require a decrease in the input rating by changing the burner injectors to
a smaller size. The chart below lists by part numbers the appropriate injectors for both LP and natural gas at various altitudes.

For Canadian installations, the Clarity Direct Vent is approved for elevations up to 1375 meters (4500 feet). When installing

the Clarity Direct Vent at altitudes above 1375 meters (4500 feet), consult the local gas distributor or the authority having
jurisdiction for proper rating methods.

NOTE: The difference in altitude derating requirements for the U.S. and Canada is simply a result of differences in testing

standards between the two countries.

If the installer must convert the unit to adjust for varying altitudes, an information sticker like the one to the right must be

filled out and affixed to the appliance at the time of conversion.

NATURAL GAS

Front

Harman

Center

Harman

Rear

Harman

Nominal Btu

Altitude

Injector Part No.

Injector Part No.

Injector Part No.

Input Rate

0-2000'

47

Standard

56

Standard

39

Standard

40,000

2000-3000'

48

3-40-25848

56

Standard

40

3-40-25840

38,400

3000-4000'

49

3-40-25849

56

Standard

41

3-40-25841

36,900

4000-5000'

49

3-40-25849

57

3-40-25857

42

3-40-25842

35,400

5000-6000'

50

3-40-25850

57

3-40-25857

42

3-40-25842

34,000

6000-7000'

50

3-40-25850

57

3-40-25857

43

3-40-25843

32,600

7000-8000'

51

3-40-25851

58

3-40-25858

43

3-40-25843

31,300

8000-9000'

51

3-40-25851

58

3-40-25858

44

3-40-25844

30,100

PROPANE

Front

Harman

Center

Harman

Rear

Harman

Nominal Btu

Altitude

Injector Part No.

Injector Part No.

Injector Part No.

Input Rate

0-2000'

56

Standard

71

Standard

53

Standard

40,000

2000-3000'

56

Standard

71

Standard

54

3-40-25854

36,900

3000-4000'

56

Standard

71

Standard

54

3-40-25854

36,900

4000-5000'

57

3-40-25857

71

Standard

54

3-40-25854

35,400

5000-6000'

57

3-40-25857

71

Standard

55

3-40-25855

32,600

6000-7000'

57

3-40-25857

71

Standard

55

3-40-25855

32,600

7000-8000'

58

3-40-25858

71

Standard

56

3-40-25856

30,100

8000-9000'

58

3-40-25858

71

Standard

56

3-40-25856

30,100

THE CONVERSION SHALL BE CARRIED OUT

BY A MANUFACTURER'S AUTHORIZED REPRE-
SENTATIVE IN ACCORDANCE WITH THE RE-
QUIREMENTS OF THE MANUFACTURER, PRO-
VINCIAL OR TERRITORIAL AUTHORITIES HAV-
IN G J URISDICTION AND IN AC COR DAN CE
WITH THE REQUIREMENTS OF THE CURRENT
EDITION OF CAN/CGA-B141.1 OR CAN/CGA-
B141.2 INSTALLATION CODES.

APPENDIX B

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Advertising