Venting, Use only approved venting – Harman Stove Company 929 DV User Manual

Page 5

Advertising
background image

5

Use Only Approved Venting

The Clarity Direct Vent Gas Heater has been tested

and is listed for installation with Simpson Duravent GS vent-
ing components. The Simpson Duravent GS warranty will
be voided, and serious fire, health, or other safety hazards
may result from any of the following actions:

• Installation of any damaged Duravent GS component.

• Unauthorized modification of the Duravent GS System.

• Installation of any component part not manufactured or

approved by Simpson Duravent.

• Installation other than as instructed by Simpson Duravent

and the appliance manufacturer.

Consult your local building codes before beginning the

installation, and follow the manufacturer's instructions ex-
actly. The following Simpson Duravent GS 4" X 6 5/8" vent-
ing components are approved for use with the Clarity Di-
rect Vent Gas Heater.

SIMPSON DURA-VENT COMPONENT NO.

Basic Termination Kit .......................................................970
Horizontal Termination Kit A...........................................971
VerticalTermination Kit A.................................................973
Horizontal Square Termination Cap.................................984
VerticalTermination Cap ...................................................983
Snorkel Termination Cap, 36" Vertical Rise .....................981
Snorkel Termination Cap, 14" Vertical Rise .....................982
Vinyl Siding Standoff .......................................................950
Wall Thimble .....................................................................942
Round Ceiling Support/Wall Thimble Cover ..................940
Cathedral Ceiling Support Box ........................................941
Storm Collar ......................................................................953
Firestop Spacer.................................................................963
Adjustable Roof Flashing, 0/12-6/12 pitch .....................943
Steep Roof Flashing, 7/12-12/12 pitch.......................... 943S
Wall Strap .........................................................................988
Designer Series Trim Kits .......................... 3951, 3952, 3953,

3960, 3961, 3962

High Wind Vertical Termination Cap ...............................991
Low Profile Termination Cap............................................980

DIRECT VENT PIPE LENGTHS

DURA-VENT COMPONENT NO.

GALVANIZED

BLACK

6" length

NA

908B

9" length

NA

907B

12" length

906

906B

24" length

904

904B

36" length

903

903B

48" length

902

902B

11-14 5/8" Adjustable

-

911B

45° Elbow

945

945B

90° Elbow

990

990B

The Clarity Direct Vent should be installed with no more

than 12 joints and 2 elbows. The elbows may be either 45°
or 90°.

The Clarity Direct Vent must not be connected to a chim-

ney flue serving any other appliance.

V

e

rt

ic

al

r

is

e

(

fe

e

t)

Horizontal run (feet)

WARNING: The flow of ventilation air must not be

obstructed.

Horizontal and Vertical Venting Requirements

The maximum horizontal run allowed for the Clarity Di-

rect Vent is 10 feet. The maximum vertical rise and maxi-
mum total vent length is 30 feet. The horizontal and vertical
lengths of venting must fall within the shaded portion of the
chart below:

Restr icto r

plates

sup plied

by

Har man

(Part No. G218) may be added in straight vertical installa-
tions only. For each 10' of vertical rise above the first 10',
one restrictor plate may be added. No more than two
restrictor plates may be used.

For venting systems that utilize one or two el-

bows (either 45° or 90°), restrictor plates

should not be used.

For the Clarity Direct Vent, the vent/

air intake termination clearances

above the high side of an

angled roof are as follows:

Roof Pitch

Feet

Meters

Flat to 6/12

1

0.3

7/12 to 9/12

2

0.6

10/12 to 12/12

4

1.2

13/12 to 16/12

6

1.8

17/12 to 21/12

8

2.4

VENTING