Installing Flame Control Solenoid

1. Remove the screw and knob from the variable regula-

tor and discard.

2. Unscrew the nut from the regulator and discard.

3. Remove the bag containing a washer and blue and

red plungers from the side of the fl ame control sole-
noid.

4. Place washer on fl ame control solenoid (see Figure 4).

5. Insert the correct plunger (blue - natural gas, red -

propane) into the fl ame control solenoid (see Figure 4).

6. Thread the fl ame control solenoid with correct plunger

into the thread hole in the variable regulator. Turn
one to two turns only. Do not tighten or damage may
occur.

Wiring the Flame Controller

1. Connect the two leads from the fl ame control solenoid

to the orange leads from the receiver.

2. Install a manometer into the pressure tap.

3. Plug the remote receiver into the 110/120 VAC power

supply.

4. Light the fi replace as directed in the Owner’s Manual.

5. Set the manifold pressure on the gas valve by rotating

the fl ame control solenoid. Adjust until the reading on
the manometer is 3.5 inches w.c. for natural gas, or
10.0 inches w.c. for LP.

6. Tighten the jam nut (see Figure 4) to the face of the

variable regulator body.

7. Turn the main gas knob on the gas valve OFF.

8. Remove the manometer from the pressure tap and

screw the tap closed.

NOTE: All steps required for installation of the
fl ame controller MUST be done by a qualifi ed gas
service technician.

NOTE: A manometer MUST be used to set the
manifold pressure on the gas valve.