6. Advance the SET temperature on the transmitter to a

temperature of at least 2º F (1º C) above the ROOM
temperature displayed on the LCD screen and the
system fl ame will ignite.

7. Set the SET temperature to at least 2º F (1º C) below

the room temperature and the system fl ame will extin-
guish. Thereafter, it should continue to cycle on and
off thermostatically approximately every two minutes
as the ROOM temperature changes, but only when
the temperature differential between ROOM and SET
temperatures differs at least 2º F (1º C). The 2º F dif-
ferential is the factory setting.

Electronic Ignition System

1. Slide the 3-position button on the remote receiver to

the ON position. The spark electrode should begin
sparking to ignite the pilot (the pilot may ignite after
only one spark). After the pilot fl ame is lit, the main
gas valve should open and the main gas fl ame should
ignite.

2. Slide the button to OFF. The main gas fl ame and pilot

fl ame should BOTH extinguish.

3. Slide the button to REMOTE (the center position).

4. Then press the MODE button on the transmitter to

change the system to ON. The spark electrode should
begin sparking to ignite the pilot. After the pilot is lit,
the main gas valve should open and the main gas
fl ame should ignite.

5. Press the MODE button on the transmitter to OFF.

The main gas fl ame and pilot fl ame should BOTH
extinguish.

6. Press the MODE button on the transmitter to change

the system to THERMO.

7. Advance the SET temperature on the transmitter to

temperature of at least 2º F (1º C) above the room
temperature displayed on the LCD screen and the
system fl ame will ignite.

8. Set the SET temperature to at least 2º F (1º C) below

the room temperature and the system will extinguish.
Thereafter, it should continue to cycle on and off
thermostatically approximately every two minutes as
the ROOM temperature changes, but only when the
temperature differential between ROOM and SET
temperatures differ at least 2º F (1º C). The 2º F dif-
ferential is the factory setting.

This REMOTE CONTROL SYSTEM is warranted for 12
months from the date of purchase or installation to the
original purchaser to be free from defects in materials
and workmanship. Damage to the SYSTEM caused by
accident, misuse, abuse, or installation error whether
performed by a contractor, service company, or owner, is
not covered by this warranty. Seller will not be responsible
for labor charges and/or damage incurred in installation,

Timer Operation

The countdown timer will operate in either the manual ON
or THERMO mode. Once the fi replace system is in an
operating mode, set the countdown timer to turn off in 15
minutes. The timer function will allow operation to continue
until the “countdown time” on the LCD screen expires. After
15 min. elapses, the system should turn off.

repair, replacement or for incidental or consequential
damages. Batteries and any damage caused by them
are not covered by this warranty.
Some states, provinces, and nations do not allow exclu-
sion or limitations of incidental or consequential damages,
so the above limitations or exclusions may not apply. This
warranty gives you specifi c legal rights. You may have
other rights that vary by state, province or nation.

GENERAL INFORMATION

Transmitter Wall Bracket

The transmitter can be hung on a wall using the bracket
provided. Locate the bracket on an inside wall suffi -
ciently far away from direct sources of heat such as a
fi replace, incandescent lighting, or sunlight so it detects
ambient room temperatures, not a single heat source.
If the bracket is installed on a solid wood wall, drill 1/8”
pilot holes and install with the screws provided. If it is
installed on a plaster/wallboard wall, fi rst drill two 1/4”
holes into the wall, then use a hammer to tap in the two
plastic wall anchors fl ush with the wall, then install the
screws provided.

Battery Life

Life expectancy of the batteries in the transmitter should
be at least 12 months. Check batteries annually. When the
transmitter no longer operates the remote receiver from
a distance it did previously (i.e., the transmitter’s range
has decreased) the batteries should be checked.

Specifi cations

Batteries: Transmitter - 3V 2 ea.; AAA 1.5V, Alkaline

Remote - 110-120 VAC; 60Hz

Operating Frequency: 303.8 MHZ
FCC ID No.’s: Transmitter - K9L300ITX
Receiver

-

K9L3003RX

Canadian ISC ID No.’s: Transmitter - 2439 102 760

Receiver - 2439 102 760A

Service Parts List

Limited Warranty

DESCRIPTION

SERVICE PART NO.

3-PRONG ADAPTER

HTI-18-006

SOLENOID-110 VOLT HI/LO

HTI-17-006

TRANSMITTER WALL HOLDER

HTI-16-006

BATTERIES-TRANSMITTER

HTI-14-006

RECEIVER

HTI-13-006

TRANSMITTER (RCT-MLT-HNG)

HTI-12-006-HNG

TRANSMITTER (RCT-MLT-HTL)

HTI-12-006-HTL

HARDWARE PACKAGE

HTI-11-006

Advertising